Posts

Showing posts from October, 2025

PLC Not Starting After Power Outage | Troubleshooting Guide

Image
  In industrial environments, a single unexpected power interruption can bring entire production lines to a halt. When systems reboot, one of the most frustrating and time-consuming issues technicians face is when the PLC does not start after a power outage . This failure can cause machine downtime, data loss, and major operational delays. To keep control systems reliable, many facilities rely on professional PLC services to identify electrical weaknesses and design protection strategies that prevent unplanned shutdowns. This guide covers the most common 15 real-world questions engineers ask when troubleshooting PLC startup issues after a power loss — along with detailed explanations, diagnostic steps, and long-term preventive measures.  1. Why does my PLC not boot up after a power outage? When power is restored, the PLC should normally initialize automatically. However, sudden voltage dips or unstable recovery can leave the system in an undefined state. The main causes...

Protection Relay Coordination Problems Explained

Image
In industrial and utility power systems, proper protection relay coordination is essential to ensure that only the faulted section is isolated — without causing unnecessary shutdowns or widespread blackouts. However, protection relay coordination problems are among the most common and costly issues engineers face during operation, maintenance, and system upgrades. If coordination fails, a minor short circuit in a feeder can trip an upstream main breaker, stopping production and damaging equipment. This article dives deep into the real-world causes , diagnostic approaches , and practical field solutions to overcome coordination challenges in modern protection systems. 1. What Causes Protection Relay Coordination Problems in Industrial Power Systems? Coordination problems usually occur when relays operate outside their intended sequence. The main causes include: Improper time–current settings between upstream and downstream relays Incorrect current transformer (CT) or voltage ...

Overcurrent Relay Malfunctions: Causes, Diagnosis & Fixes

Image
  In industrial power systems, overcurrent relay malfunctions can lead to severe operational and safety issues — from unexpected shutdowns to unprotected equipment during real faults. These relays play a vital role in protecting feeders, motors, and transformers from excessive current. When they fail to perform correctly, both downtime and equipment damage can occur. In this article, we’ll explore the most common field questions engineers face when dealing with overcurrent relay problems, understand the root causes, and learn practical diagnostic and maintenance approaches.  1. Why is the overcurrent relay not tripping during a short circuit? This is one of the most critical issues. Possible reasons include incorrect CT polarity, relay not receiving actual current due to open CT secondary, or wrong pickup settings. In some cases, the relay may be healthy, but the trip output contact or breaker coil fails to operate. Field check: Measure actual fault current using te...

Relay Not Detecting High Impedance Faults | Causes & Solutions

Image
  Relay Not Detecting High Impedance Faults is one of the most underestimated challenges in electrical protection systems. High impedance faults generate low fault currents that often remain below the pickup thresholds of conventional relays, allowing dangerous arcing conditions to persist undetected. This issue frequently appears in aging infrastructure, long cable routes, and dry soil environments. Understanding how these faults behave, how protection logic interprets them, and how relay settings should be optimized is critical for electrical safety. Many engineers rely on guidance from a protection relay supplier when evaluating suitable functions and sensitivity levels to ensure reliable fault detection and system stability. 1. What Exactly Is a High Impedance Fault and Why Does It Go Undetected? A High Impedance Fault (HIF) occurs when a phase conductor unintentionally contacts a surface that limits the current flow. Common contact surfaces include: Dry soil Sand Asp...

Relay Not Operating During Fault: Causes & Solutions

Image
 When a protection relay fails to operate during a real fault, the consequences can be severe — prolonged fault duration, equipment damage, and major production losses. The issue of relay not operating during fault is one of the most challenging topics for protection and maintenance engineers, especially in industrial plants like steel factories, cement mills, and water treatment facilities . Understanding the real reasons behind such failures requires a structured approach that considers wiring integrity, CT/PT performance, relay logic, and trip path health. Let’s go through the most frequent real-life questions engineers ask on-site and analyze their technical explanations and corrective actions .  Why Didn’t the Relay Trip Even Though the Fault Occurred? This is the first and most common question. The relay may appear to “fail,” but the problem often lies in protection coordination . In many systems, multiple relays share the same fault path — for example, feeder a...