Root Causes of Sensor Drift in Industrial Plants

In industrial plants, sensors are the backbone of automation and control systems. Accurate readings of temperature, pressure, flow, and level are critical for process efficiency, product quality, and safety. However, sensor drift the gradual deviation of sensor output from true process values is a common challenge. If unaddressed, drift can lead to false alarms, unnecessary downtime, inefficient process control, and increased maintenance costs.

Understanding the root causes and implementing effective solutions is essential. Below are 25 key questions about sensor drift, each answered with detailed technical explanations, real-world examples, process impact, and actionable solutions.

1. How does temperature during startup cause sensor drift?

Temperature-induced drift occurs when sensors are exposed to rapid temperature changes, causing the sensing element and housing to expand or contract at different rates. RTDs experience resistance changes, thermocouples show junction voltage offsets, and thermistors can respond non-linearly at extremes.

In cement kiln startups, temperatures can rise several hundred degrees in minutes. Engineers often see spikes in readings that may trigger false alarms or cause automated control systems to make inappropriate adjustments, disrupting process stability, wasting energy, and compromising product quality.

Mitigation includes using high-temperature-rated sensors, thermal isolation or shields, controlled ramp-up procedures, and post-startup stabilization before feeding data to the PLC/DCS. Periodic recalibration after thermal cycling ensures long-term reliability.

2. What is the effect of thermal shock on sensor accuracy?

Thermal shock happens when a sensor is exposed to sudden temperature changes, causing mechanical stress. Thermocouples may develop micro-cracks, and RTDs can bend, resulting in persistent drift.

In water treatment plants, introducing hot water into cold pipelines causes temporary but noticeable deviations in temperature and level readings. Ignoring this can trigger alarms, affect flow control, or compromise batch records. Repeated thermal shocks also shorten sensor lifespan.

Prevention involves gradual ramp-up of temperature, using sensors designed for thermal shock, thermal shields, and recalibration after extreme temperature changes. Matching expansion coefficients between sensor elements and housing reduces stress.

Read about: Ultimate Guide to Motor Commissioning for High-Power Industrial Motors

3. How does line pressure or load affect pressure transmitter readings?

Diaphragm-based pressure transmitters deform under line pressure, and the deformation can create offsets. Fluid viscosity, density, and transient pressure spikes exacerbate drift.

Chemical plants filling viscous tanks often report elevated readings, leading to false alarms, improper pump control, or batch inaccuracies. Repeated loading accelerates mechanical fatigue, causing long-term drift.

Mitigation strategies include reinforced diaphragms, zero/span checks under operating conditions, avoiding oversized impulse lines, following manufacturer torque guidelines, and monitoring pressure trends for early detection.

4. How does flow turbulence lead to unstable sensor readings?

Flow meters are sensitive to turbulence from bends, pumps, and valves. Vortices and velocity fluctuations can cause erratic readings or drift.

Pulp and paper mills have experienced 3–5% flow meter drift due to inadequate upstream straight-run piping. Drift can affect pump control, chemical dosing, and energy efficiency.

Solutions include flow conditioners, proper piping design, adequate straight runs, CFD studies for complex installations, and correct sensor placement to reduce turbulence impact.

5. Why do level sensors drift when fluid density changes?

Differential pressure level transmitters calculate levels based on fluid density. Variations in temperature, composition, or chemical additives cause drift even if liquid height remains constant.

Water treatment plants switching between fresh water and brine solutions frequently see level reading errors. Drift may lead to false alarms or inaccurate batching, affecting product quality and process control.

Mitigation includes density-compensated transmitters, recalibration for different media, or using ultrasonic/radar sensors less sensitive to density. Continuous density monitoring ensures accuracy.

6. How does high humidity affect sensor performance?

High humidity can corrode terminals and degrade insulation, causing leakage currents in analog 4–20 mA loops. Coastal desalination plants report slow, persistent drift.

Impact: fluctuating readings can cause incorrect flow, level, or pressure control, trigger unnecessary alarms, and lead to inefficient operation.

Prevention includes IP-rated junction boxes, desiccants, proper sealing of cable entries, and regular inspections to maintain loop integrity.

7. Can clogged filters cause sensor drift?

Yes. Filters or strainers upstream of sensors can block flow or create false pressure differences.

Cement plant hoppers, for example, drifted due to blocked air filters, causing level misreadings and unnecessary alerts. Drift affects automation control and batch consistency.

Solutions: regular cleaning, preventive maintenance, bypass lines for verification, and monitoring filter differential pressure as early warning.

8. How do dead legs in piping affect sensor readings?

Dead legs are stagnant fluid sections where temperature gradients, density changes, and trapped gases can occur, causing pressure and level sensor drift.

Petrochemical plants report slow drift in dead-leg areas, affecting tank monitoring and flow control.

Mitigation includes avoiding dead legs in design, installing purge or recirculation connections, and monitoring process variables to detect stagnation.

9. What is the impact of mechanical vibration on sensors?

Vibration fatigues sensor elements or mounts, producing permanent offsets. Mining operations near crushers and mills experience long-term drift in pressure and level transmitters.

Drift may cause inaccurate alarms, repeated pump cycling, or batch errors. Solutions: vibration-dampening mounts, reinforced housings, vibration-rated sensors, and periodic inspection to detect mounting issues.

10. How does sensor aging contribute to drift?

Over time, sensors experience oxidation, insulation degradation, and mechanical creep, reducing accuracy. RTDs older than five years may require frequent recalibration.

Impact: inaccurate readings affect process stability, safety, and efficiency. Lifecycle management is crucial. Solutions: sensor lifecycle tracking, trend analysis of historical data, proactive replacement, and regular calibration schedules.

11. Can corrosion in impulse lines cause sensor drift?

Yes. Corrosion reduces line diameter, introduces turbulence, and creates micro-leaks, affecting DP transmitters.

Chemical plants have reported inaccurate pressure readings due to corroded impulse lines, impacting control loops and batch quality.

Mitigation: use corrosion-resistant materials, install flush points, conduct regular inspections, and verify chemical compatibility.

12. Do poorly sealed cable glands lead to drift?

Improperly sealed cable glands allow moisture ingress, leading to leakage currents in analog loops.

Coastal or high-humidity plants often experience slow drift in affected sensors. Impact: unreliable readings and false alarms.

Solutions: use IP-rated glands, sealing compounds, proper installation techniques, and regular inspections.

13. How do high ambient temperatures affect sensor readings?

High temperatures accelerate electronic aging, insulation degradation, and drift.

Cement plants near kilns notice sensor offsets during summer, affecting temperature control and process stability.

Prevention: select high-temperature-rated sensors, provide ventilation, shield from direct heat, and schedule regular recalibration.

14. How does mechanical stress on probes cause drift?

Misalignment, bending, or overtightening permanently shifts readings.

Water treatment pressure transmitters installed too tightly on flanges exhibited immediate offsets.

Mitigation: follow manufacturer installation guidelines, proper torque, alignment, and periodic inspection.

15. How does EMI/RFI interfere with sensor signals?

Electromagnetic interference induces unwanted currents in sensor loops, causing erratic drift.

Petrochemical plants near high-power drives report analog signal instability.

Prevention: shielded cables, proper grounding, separation from power lines, and routine loop checks.

16. Can incorrect grounding cause drift?

Yes. Ground loops introduce voltage offsets into analog loops.

Impact: fluctuating readings can trigger alarms or incorrect process actions.

Solution: use single-point grounding, verify loop continuity, and inspect grounding regularly.

17. How do loose terminals affect sensor readings?

Loose or corroded terminals generate intermittent contacts and alter loop resistance.

Impact: erratic readings, false alarms, and unstable process control.

Mitigation: regular inspections, proper torqueing, and cleaning of connections.

18. Can improper shield grounding cause sensor drift?

Yes. Multi-point shield grounding injects unwanted currents into loops.

Impact: constant or slow offsets in sensor readings.

Solution: single-point grounding at the control panel prevents offsets.

19. How does changing loop resistance over time affect drift?

Aging wires, temperature cycling, or corrosion increase loop resistance, producing slow drift.

Impact: analog readings shift over weeks or months, affecting automation.

Prevention: use correct wire sizing, corrosion-resistant conductors, and monitor loop resistance.

20. Why does post-calibration drift occur?

Even after calibration, drift can happen due to environmental factors, aging, or improper procedure.

Impact: short-term inaccurate readings, false alarms, and unstable control.

Solution: in-situ calibration under real process conditions, temperature and pressure stabilization before calibration.

21. What do span or zero shifts indicate?

Zero or span shifts often indicate sensor aging, electronics degradation, or calibration errors.

Impact: incorrect level, pressure, or temperature readings affecting process control.

Mitigation: monitor historical trends, recalibrate when shifts appear, and replace aging components.

22. Can incorrect calibration procedures cause drift?

Yes. Using wrong reference standards, skipping stabilization, or ignoring environmental conditions leads to drift.

Impact: inaccurate process readings, wasted energy, or batch errors.

Solution: follow manufacturer calibration procedures, allow stabilization, and use proper reference instruments.

23. How does batch vs. continuous operation influence sensor drift?

Batch processes involve frequent start/stop cycles, creating thermal and mechanical stress. Continuous processes are more stable.

Impact: batch processes see faster drift, affecting accuracy in chemical dosing or heating/cooling loops.

Solution: account for operational type in calibration and maintenance schedules.

24. Can faulty transmitter electronics cause sensor drift?

Yes. Component aging, heat damage, or moisture ingress can lead to erratic readings.

Impact: alarms, false shutdowns, or control errors.

Solution: replace faulty electronics, inspect housing, and ensure proper environmental protection.

25. How does improper installation or loop configuration contribute to drift?

Sensors near elbows, valves, or dead legs experience trapped gas or flow disturbances.

Impact: inaccurate readings, mis-triggered alarms, and inefficient control loops.

Solution: proper routing, loop verification, and installation checks, avoiding dead legs and using recommended impulse line lengths.

Conclusion

Sensor drift is inevitable in industrial plants, but it can be effectively managed. Best practices include:

  1. Regular inspections for physical damage, corrosion, or moisture ingress.

  2. Proper calibration under real process conditions.

  3. Correct installation with grounding, shielding, and alignment.

  4. Environmental protection against heat, humidity, and vibration.

  5. Predictive monitoring for early detection and preventive maintenance.

By addressing mechanical, electrical, environmental, and process-related factors, engineers can ensure accurate readings, reduce downtime, improve efficiency, and maintain safe, stable operations in cement, water treatment, petrochemical, and other industrial plants.